Fire alarm systems / Control panels |
 |
|
|
|
|
|
|
 |
|
J408-4
Conventional Control
Panels |
 |
|
 |
4
zone fire control panel |
|
4controlled, balanced,
bypassable input
zones |
|
Power supply: 230 Vac ±10% |
|
RS485
bus |
|
27.6
Vdc 1.5 A switching supply/battery-charger |
|
Compartment
for two 12 V 7 Ah batteries |
|
Dimensions
(wxhxd): 354x280x100 mm |
|
Weight
(without batteries): max. 4,5 Kg |
|
|
 |
 |
|
|
- FeaturesConforms with EN54
- Up to to 21 devices can be connected to each zone:
conventional fire
detectors, alarm buttons, gas detectors
- Gas zone compatible with 4 – 20 mA gas detectors
- One alarm-repeat output (open collector) for each
input zone
- Manual call point recognition
- Signals missing detectors
- 2 supervised, silenceable, bypassable 24 V alarm
output for the activation
of piezoelectric sirens, fire bells and flashers
- Silenceable fault-warning output for the activation
of
signalling and dsauxiliary devices
- Supervised fire output for telephone dialler activation
- Programmable open-collector output
- Dry contact alarm-relay for the activation of auxiliary
devices
- Day/Night mode
- Alarm verification time
- Programmable restoral and reset times
- Programmable from PC or keypad
- 50 event log viewed via PC
- Alarm/fault memory activated until next reset
- Command for silencing sirens
- Keypad commands require key or pin code
|
|
 |
|
J408-8 Conventional Control
Panels |
 |
|
 |
8
zone fire control panel |
|
8 controlled, balanced,
bypassable input
zones |
|
Power supply: 230 Vac ±10% |
|
RS485
bus |
|
27.6
Vdc 1.5 A switching supply/battery-charger |
|
Compartment
for two 12 V 7 Ah batteries |
|
Dimensions
(wxhxd): 354x280x100 mm |
|
Weight
(without batteries): max. 4,5 Kg |
|
|
 |
 |
|
|
- FeaturesConforms with EN54
- Up to to 21 devices can be connected to each zone:
conventional fire
detectors, alarm buttons, gas detectors
- Gas zone compatible with 4 – 20 mA gas detectors
- One alarm-repeat output (open collector) for each
input zone
- Manual call point recognition
- Signals missing detectors
- 2 supervised, silenceable, bypassable 24 V alarm
output for the activation
of piezoelectric sirens, fire bells and flashers
- Silenceable fault-warning output for
the activation of
signalling and dsauxiliary devices
- Supervised fire output for telephone dialler activation
- Programmable open-collector output
- Dry contact alarm-relay for the activation of auxiliary
devices
- Day/Night mode
- Alarm verification time
- Programmable restoral and reset times
- Programmable from PC or keypad
- 50 event log viewed via PC
- Alarm/fault memory activated until next reset
- Command for silencing sirens
- Keypad commands require key or pin code
|
|
|
|
http://www.bentelsecurity.com |
 |
|
 |
|
 |
|
J424
Conventional Control
Panels |
 |
|
 |
Expandable
fire control panel. |
|
8 controlled, balanced, bypassable
input zones expandable to
24 by means of two 8 zone expanders |
|
Optional backlit display |
|
RS485
bus |
|
Power
supply: 230 Vac ±10% |
|
27.6
Vdc 2.5 A switching supply/battery-charger |
|
Compartment
for two 12 Vdc 17 Ah batteries |
|
Dimensions
(wxhxd): 422x502x116 mm |
|
Weight
(without batteries): max. 8.5 Kg |
|
|
 |
 |
|
|
- Conforms with EN54
- Up to 21 devices can be connected to each zone:
conventional fire
detectors, alarm buttons, gas detectors
- Gas zone compatible with 4 – 20 mA gas detectors
- One alarm-repeat output (open collector) for each
input zone
- Manual call point recognition
- Signals missing detectors
- 2 supervised, silenceable, bypassable 24 V alarm
output
for the activation of piezoelectric sirens, fire bells
and flashers
- Silenceable fault-warning output for the activation
of signalling
and auxiliary devices
- Supervised fire output for telephone dialler activation
- Programmable open-collector output
- Dry contact alarm-relay for the activation of auxiliary
devices
- Day/Night mode
- Alarm verification time
- Programmable restoral and reset times
- Programmable from PC or keypad
- 50 event log viewed via PC
- Alarm/fault memory activated until next reset
- Command for silencing sirens
- Keypad commands require key or pin code
|
|
 |
|
J400-EXT |
 |
|
 |
Extinguisher module with microprocessor
control |
|
Output for electro-valves controlled by
logic (AND/OR) between the status of the
control panel zones |
|
Programmable extinguishment delay |
|
Output
signals: extinguishment delay, extinguishment
and released |
|
Input
for the forced activation of the extinguishment
devices - Input for the pressure switch |
|
Fault
signalling on pressure-switch supply line |
|
Fault
signalling on input lines |
|
Bypass
of extinguishment devices in the event of
false alarm |
|
Inputs
for selecting manual or automatic mode,
extinguishment inhibit and power supply
supervision |
|
|
 |
 |
|
|
|
|
http://www.bentelsecurity.com |
 |
|
 |
|
|
 |
|
J400EXP8 |
 |
|
 |
|
|
8
zones expander module for J424 panels
(8 balanced, bypassable fire zones) |
|
|
|
|
 |
 |
|
|
|
|
http://www.bentelsecurity.com |
 |
|
 |
|
|
|
  |
|